SOP for Compression Machine 20 Station (Single Rotary Type) : Pharmaguideline

Online GMP Courses with Certificate

ENROLL

SOP for Compression Machine 20 Station (Single Rotary Type)

Standard operating procedure of compression machine 20 station (Single Rotary Type) used for compression of tablets.

1.0 OBJECTIVE

To lay down the procedure for Operation of Compression Machine 20 station (Single Rotary Type).

2.0 SCOPE

This SOP shall be applicable for the operation of Compression Machine 20 station (Single Rotary Type) in Compression area at Production department.

3.0 RESPONSIBILITY

3.1 Execution: Operator
3.2 Checking: Production Pharmacist & Above

4.0 ACCOUNTABILITY

HOD-Production / Assigned Designee

5.0 PROCEDURE

5.1 PRECAUTIONS

5.1.1 Ensure that electrical supply is disconnected before starting machine setting.
5.1.2 The machine should not be operated without guards in the correct position.
5.1.3 Proper lubrication must be maintained throughout the compression process.
5.1.4 Hopper should be covered immediately after loading of granules.
5.1.5 Container of lubricated granules and compressed tablets should be kept covered and duly labeled.
5.1.6 During compression containers of lubricated granules should be used serially as per the container numbers on the label.

5.2 SETTING PROCEDURE FOR ROUND PUNCHES

5.2.1 Examine machine for cleanliness including rinse water results, dust-extraction unit and area. Check punches and dies cleanliness.
5.2.2 Rotate hand wheel and check that turret rotates freely.
5.2.3 Check that pressure wheels are free and pressure is released.
5.2.4 Check that sockets of upper / lower punches and dies are properly cleaned.
5.2.5 Fit dies using die rod. Ensure that die is fitted in the turret, Tighten die holding screws.
5.2.6 Fit lower punches using a thin coat of Food Grade Oil on punch barrel. Ensure that punches are ‘freely moving’ by pushing the punch tips through the die and allowing the punches to drop back freely on its own weight. Tighten lower punches with plugs using anti-turning strip.
5.2.7 Rotate hand wheel and check that all lower punches moves freely.
5.2.8 Fit upper punches.
5.2.9 Close lower punch guard covers and fit the feed frame and check the clearance with the turret.
5.2.10 Fix hopper in such way, so as to give 3-5 mm clearance from turret for the free flow of granules to the feed frame.
5.2.11 Rotate hand-wheel and check that machine is free.
5.2.12 Fit the acrylic guard. Check the condition of oil cups for any spillage of oil, which may contaminate the product. Clean if necessary.
5.2.13 Check tablet and granules containers, and polythene bags, etc. for cleanliness.
5.2.14 Affix the Status label with Product Name, Batch Details to equipment, area and get the clearance from Q.A.
5.2.15 Load granules in the hopper, Rotate machine by hand to fill feed-frame and dies.
5.2.16 Apply pressure just to form the tablet. Check the weight of the tablet. Further, increasing the pressure to produce a required thickness of the tablet.
5.2.17 Put “ON” electric supply and press the green button of the machine and check for required Physical Appearance, Thickness, Hardness, Average Weight, Weight Variation, disintegration time, friability and record in the BMR.
5.2.18 After setting all parameters, the pharmacist should counter check the same.

5.3 SETTING INSTRUCTIONS FOR SHAPED PUNCHES

5.3.1 In case of shaped punch first fit the upper punches by taking out take off plates and adjusts the die accordingly so that punch insertion is free in the die. Then keeping upper punch tip in the die tightens the die locking screws. After fitting of all upper punches, refix the take-off plate. Then insert the lower punches through the bottom by ensuring the free movement of the punches and then fit with punch holding plugs and fix the anti-turning strip.
5.3.2 Rest all the procedure remains same as that of round shape punches.

5.4 TABLET PARAMETER CHECKING

5.4.1 After the setting is complete. Put “ON” the mains. start the machine and check for following parameters at a specified frequency.
5.4.2 For Physical Appearance check the surface of all tablets obtained in one rotation for the elegance and absence of defects such as sticking, picking and correctness of embossing. Appearance to be checked after every two hours and after every break.
5.4.3 Weight Variation of 20 tablets after every 15 min.
5.4.4 Individual weight of tablets (weight variation) initially & after every 2 hour of one full rotation.
5.4.5 Thickness of tablets in one full rotation at the beginning of the batch and then for not less than 3 tablets afterwards every half an hour.
5.4.6 Hardness for not less than 3 tablets every half an hour.
5.4.7 Friability for tablets at the start and afterwards every two hours.
5.4.8 Disintegration time for 6 tablets at the start and afterwards every two hours.
5.4.9 After the compression is complete. Put “OFF” the mains.
5.4.10 Affix “To be Cleaned” label. & fill the “Equipment Log Book”.
Note: For Friability 6.50gm tablets to be taken if the average weight of the tablet is < to 650 mg or 10 tablets to be taken for friability test if the average weight is > 650 mg per tablet.

6.0 ABBREVIATIONS

6.1 SOP: Standard Operating Procedure
6.2 BMR: Batch Manufacturing Record
6.3 Q.A.: Quality Assurance
6.4 HOD: Head of The Department





Ankur Choudhary is India's first professional pharmaceutical blogger, author and founder of pharmaguideline.com, a widely-read pharmaceutical blog since 2008. Sign-up for the free email updates for your daily dose of pharmaceutical tips.
.moc.enilediugamrahp@ofni :liamENeed Help: Ask Question


2 comments: Post Yours! Read Comment Policy ▼

  1. Thanks and very good

    ReplyDelete
  2. Its is really interesting to read something on SOP for Tablet Compression Machine.I really visit your blog again.Thanks for sharing.
    Compression Machine

    ReplyDelete

Please don't spam. Comments having links would not be published.


Popular Categories

QA SOPs QC SOPs Micro SOPs HVAC Production SOPs Stores SOPs Checklists Maintenance SOPs HPLC Sterile GLP Validation Protocols Water System GDP Regulatory Maintenance Calibration Warning Letters Education B.Pharmacy
Online Courses


Follow Pharmaguideline


DOCUMENTS

PHARMACEUTICAL DOCUMENTS




Editable Pharmaceutical Documents in MS-Word Format. Ready to use SOPs, Protocols, Master Plans, Manuals and more...

View


adsbypg


Recent Posts