Standard operating procedure to clean the Octagonal Blender.

1.0 OBJECTIVE:

To lay down the cleaning procedure for Octagonal Blender.

2.0 SCOPE:

This SCP shall be applicable for Octagonal Blender in Blending area in Production department.

3.0 RESPONSIBILITY:

3.1 Execution :Operator
3.2 Checking :Pharmacist and Above

4.0 ACCOUNTABILITY:

HOD-Production

5.0 PROCEDURE:

5.1 Put “OFF” the electric supply and cover all the electrical parts with poly bags.
5.2 Remove the lid and open butter fly valve assembly.
5.3 Wipe off residual powder by dry lint free cloth.
5.4 Wash with 50 liter Potable water at least two times till all the residue is washed off. Use 2.5 % “Teepol” solution & scrub the parts if required then wash with 25 liter hot water.
5.5 Finally rinse with about 100 liter purified water.
5.6 Dismantle the butter fly valve and lid wash with 5 liter Potable water. Finally rinse with 5 liter purified water.
5.7 Wipe off all the parts with 70 % v/v solution of Isopropyl Alcohol (IPA).
5.8 Affix “Cleaned” label and fill the “Equipment Log Book”.
5.9 Re-cleaned If not used within 72 hours.

6.0 ABBREVIATIONS:

SCP :Standard Cleaning Procedure
IPA :Isopropyl Alcohol