    SOP for Leak Test of Strip, Blister and Alu – Alu Blister Sealing

    Standard operating procedure to determine the leak in strip and blister by leak test using leak test apparatus.

    1.0 OBJECTIVE

    To lay down the procedure for leak test of strip, blister and alu–alu blister sealing.

    2.0 SCOPE

    This SOP shall be applicable to Production and Quality Assurance Dept.

    3.0 RESPONSIBILITY

    Supervisor Production/Supervisor Q.A

    4.0 ACCOUNTABILITY

    Sr. Manager Quality Assurance

    5.0 PROCEDURE

    5.1 Perform the leak test at an interval of about two hours.
    5.2 Collect strips from packing machine according to the number of pockets present in the forming roller.
    5.3 Tie the bunch of strips with rubber band put them in a vacuum desiccator.
    5.4 Fill 1/3 of the volume of the vacuum desiccator with water and add a few drops of methylene blue and mix it to give a light blue color.
    5.5 Place the strips in the desiccator and ensure that they are completely immersed in water.
    5.6 Connect the rubber tubing of the vacuum pump to the side opening of the sleeve.
    5.7 Switch on the mains of vacuum pump and apply vacuum for 30 seconds on 15 inches of Hg pressure (negative pressure)
    5.8 Move the side-opening knob to ensure vacuum and remove the rubber tubing from the sleeve.
    5.9 Gradually release the vacuum and remove the strips from the water after 3 minutes.
    5.10 Observe the pockets for Leakage and Count the number of pockets leaked and calculate the % of pockets leaked with the following equation:
        No. of Pockets leaked x 100
    ------------------------------------
            Total No. of Pockets
    5.11 Record the findings in the batch manufacturing record and advise to packing department accordingly.

    6.0 ABBREVIATIONS

    6.1 SOP: Standard Operating Procedure
    6.2 QA: Quality Assurance
    6.3 QC: Quality Control
    6.4 Dept.: Department
    6.5 Hg: Mercury
    Get editable documentsView List

    2 comments: Post Yours! Read Comment Policy ▼

    1. Not more than:
      1. 0 % (Alu-Alu blister & Sachet) At 30 cm of mercury ≅ 11.81 inch of Hg
      2. 2% (Alu-PVDC)at 30 cm of mercury ≅ 11.81 inch of Hg
      3. 2% (Alu-PVC blister) at 38 cm of mercury ≅ 14.96 inch of Hg
      4. 0% (Alu-Alu strip)at 53 cm of mercury ≅ 20.86 inch of Hg
      5. 0% (Sealed bottle) at 38 cm of mercury ≅ 14.96 inch of Hg

      ReplyDelete
      Replies
      1. from which official resource above mentioned criteria taken?

        Delete

    Please don't spam. Comments having links would not be published.


    Popular Categories 🏷️

    QA SOPs QC SOPs Micro SOPs HVAC Production SOPs Stores SOPs Checklists Maintenance SOPs HPLC Sterile GLP Validation Protocols Water System GDP Regulatory Maintenance Calibration Warning Letters Education B.Pharmacy
    Online Courses Salary Calculator
    Follow on Whatsapp


    Certificate Courses 🎖️

    Pharmaceutical Courses

    Follow Pharmaguideline


    DOCUMENTS 📋

    PHARMACEUTICAL DOCUMENTS




    Editable Pharmaceutical Documents in MS-Word Format. Ready to use SOPs, Protocols, Master Plans, Manuals and more...

    View


    adsbypg


    GET APP FOR NEWS UPDATES


    Android App