    SOP for Passivation of Purified Water Storage Tank and Distribution Piping

    Standard operating procedure of passivation of purified water storage tank and distribution system with nitric acid and hot waterto decontaminate.

    1.0 OBJECTIVE

    To lay down the procedure for the passivation of purified water storage tank and distribution piping.

    2.0 SCOPE

    This SOP shall be applicable for the purified water storage tank and distribution piping.

    3.0 RESPONSIBILITY

    Operator /Engineer/ Executive

    4.0 ACCOUNTABILITY

    Head of Department

    5.0 PROCEDURE

    5.1 Collect the Reverse Osmosis (RO) product water in the purified water storage tank.
    5.2 Flush the storage tank with RO water by filling and draining the tank twice.
    5.3 Again take the fresh RO water in the storage tank and flush the interconnecting piping in the open loop and then in the closed loop.
    5.4 Drain out the storage Tank.
    5.5 Prepare the Nitric acid solution (about 10 % solution) in the purified water storage tank. Take about 350 liters of RO product Water; add 35 liters of Nitric acid.
    5.6 Circulate the above Nitric acid solution in the interconnecting piping in the closed loop distribution system for 2.0 hours.
    5.7 Stop the distribution pump and drain all the Nitric acid solution.
    5.8 Collect the RO water into purified water storage tank and flush the distribution system till the pH is in between 7-8 and then drain the water.
    5.9 Collect the RO water into the purified water storage tank and heat it to 80ºC to 85ºC and circulate through distribution loop system for a minimum of 1 hour to sanitize the loop system.
    5.10 Check the pH values of RO water and outlet of the storage tank.
    5.11 If the pH values of RO water and outlet of storage tank differ by more than +/- 0.5, again flush the distribution system till traces of Nitric acid are removed. pH should be within +/- 0.5 of the RO outlet water.
    5.12 Use proper hand gloves duly disinfected with IPA or chlorinated water while preparing the solution.
    5.13 Use safety goggle and mask while preparing the solution.

    6.0 ABBREVIATIONS

    6.1 SOP: Standard Operating Procedure
    6.2 RO: Reverse Osmosis
    6.3 IPA: Iso Propyle Alcohol
    Also see: How to Remove Pathogenic Bacteria from Water Systems
    Get editable documentsView List

    1 comment: Post Yours! Read Comment Policy ▼

    1. sir is any guideline for passiavtion of PWS, please reply

      ReplyDelete

    Please don't spam. Comments having links would not be published.


    Popular Categories 🏷️

    QA SOPs QC SOPs Micro SOPs HVAC Production SOPs Stores SOPs Checklists Maintenance SOPs HPLC Sterile GLP Validation Protocols Water System GDP Regulatory Maintenance Calibration Warning Letters Education B.Pharmacy
    Online Courses Salary Calculator
    Follow on Whatsapp


    Certificate Courses 🎖️

    Pharmaceutical Courses

    Follow Pharmaguideline


    DOCUMENTS 📋

    PHARMACEUTICAL DOCUMENTS




    Editable Pharmaceutical Documents in MS-Word Format. Ready to use SOPs, Protocols, Master Plans, Manuals and more...

    View


    adsbypg


    GET APP FOR NEWS UPDATES


    Android App