SOP for Preparation of Working Standards | Pharmaguideline
  •   Pharmaguideline Courses Start Learning
  • Apr 17, 2021

    SOP for Preparation of Working Standards

    Standard operating procedure to manage the reference standard and prepare the working standard used for quantitative analysis.

    1.0 OBJECTIVE

    To lay down the procedure for Handling of Reference standard and management of Working standard.

    2.0 SCOPE

    This SOP shall be applicable to Quality Control Dept.

    3.0 RESPONSIBILITY

    Quality Control Supervisor

    4.0 ACCOUNTABILITY

    Sr. Manager Quality Assurance.

    5.0 PROCEDURE

    5.1 Reference Standard Management

    5.1.1 Procure reference standard from authorized sources for preparation and standardisation of working standard. Write the details in the register and maintain the Certificate of Reference standard.
    5.1.2 Store all Reference standards in tight containers protected from heat, air, moisture and light and keep them in a properly greased vacuum desiccator containing self-indicating dried silica gel at the bottom.
    5.1.3 Store the desiccators in an air-conditioned place.

    5.2 Preparation of working standard

    5.2.1 Select an approved batch of respective raw material. Collect the required amount of sample and mix thoroughly.
    5.2.2 Carry out tests as per protocol. Perform assay five times. RSD of the five values of assay shall not be more than 2.
    5.2.3 Compare the analysis results with Reference standard / Supplier’s working standard (if Reference standard is not available) as per the following procedure:
    a) Reference standard is available
    i) Compare identification test (IR/HPLC/TLC ) of the raw material against the reference standard.
    ii) Carry out assay of the raw material taking reference standard as standard whenever possible.
    b) Supplier working standard is available.
    i) Compare identification test results and purity results (IR/HPLC/TLC) of selected raw material against Supplier’s working standard.
    ii) Carry out assay of the raw material Considering Supplier’s working standard as standard.
    5.2.4 The final certificate of Analysis for working standard shall have the following details: Name of material, Batch no., Mfg date, Exp date, Mfg by, AR. No., Date of opening, Use Before, Storage conditions etc.
    5.2.5 Each working standard vial shall also be labeled with the above details.
    5.2.6 Each vial of working standard shall contain not more than 5 gms of the working standard.
    5.2.7 No vial shall be used after two months from the date of opening.
    5.2.8 Consumption record shall be maintained whenever a working standard is used.
    5.2.9 No working standard shall be used for more than two years or when it gets consumed, whichever is earlier.
    5.2.10 Each lot of working standard shall be evaluated once in two years.

    6.0 ABBREVIATION

    6.1 SOP: Standard Operating Procedure
    Get editable documentsView List

    No comments:

    Post a Comment

    Please don't spam. Comments having links would not be published.


    Popular Categories ๐Ÿท️

    QA SOPs QC SOPs Micro SOPs HVAC Production SOPs Stores SOPs Checklists Maintenance SOPs HPLC Sterile GLP Validation Protocols Water System GDP Regulatory Maintenance Calibration Warning Letters Education B.Pharmacy
    Online Courses Salary Calculator
    Follow on Whatsapp


    Certificate Courses ๐ŸŽ–️

    Pharmaceutical Courses

    Follow Pharmaguideline


    DOCUMENTS ๐Ÿ“‹

    PHARMACEUTICAL DOCUMENTS




    Editable Pharmaceutical Documents in MS-Word Format. Ready to use SOPs, Protocols, Master Plans, Manuals and more...

    View


    adsbypg


    GET APP FOR NEWS UPDATES


    Android App