    1.0 OBJECTIVE

    To lay down the procedure for operation and cleaning of LAF unit in Sampling Room at Raw Material Store.

    2.0 SCOPE

    This SOP shall be applicable for operation and cleaning of LAF unit in Sampling Room at Stores Department.

    3.0 RESPONSIBILITY

    Stores Assistant/QC Pharmacist

    4.0 ACCOUNTABILITY

    Head of Department

    5.0 PROCEDURE

    5.1 Before starting the activity, store person shall ensure that the LAF unit is clean.
    5.2 Check “CLEANED” status label.
    5.2 Store person shall check and ensure for the ‘Zero’ reading in all three magnehelic gauges of LAF unit, when the LAF unit is switched off.
    5.3 Switch on the Blower.
    5.4 Switch on the Light.
    5.5 Allow the LAF to run for at least 15 minutes before the start of observation & recording:

    PRESSURE DROP ACROSS FINAL (HEPA) FILTER

    Limit: 8 mm – 16 mm
    Observe the reading and record the pressure of HEPA filter.
    Incase reading is out of limit, Stop the operation & intimate Head-Store and Maintenance for rectification.

    PRESSURE DROP ACROSS INTERMEDIATE FILTER

    Limit: 3 mm – 6 mm
    Observe the reading and record.
    Incase reading is out of limit, clean /replace the intermediate filter.

    PRESSURE DROP ACROSS PREFILTER FILTER

    Limit: 1 mm – 6 mm
    Observe the reading and record.
    Incase reading is out of limit, clean /replace the pre filter.
    5.6 Store person shall transfer the container one at a time from which the material is to be sampled under the LAF Unit.
    5.7 After completion of sampling as per the standard sampling plan, well close the containers and then take out from the LAF unit.
    5.8 Put “OFF” the LAF after completion of sampling and clean the LAF as per the SOP & record the cleaning activity.

    6.0 ABBREVIATIONS

    6.1 SOP – Standard operating procedure
    6.2 HEPA – High efficiency particulate air
    6.3 mm – Millimeter
    6.4 LAF – Laminar air flow
    Get editable documentsView List

    No comments:

    Post a Comment

    Please don't spam. Comments having links would not be published.


    Popular Categories ๐Ÿท️

    QA SOPs QC SOPs Micro SOPs HVAC Production SOPs Stores SOPs Checklists Maintenance SOPs HPLC Sterile GLP Validation Protocols Water System GDP Regulatory Maintenance Calibration Warning Letters Education B.Pharmacy Regulatory Updates
    Online Courses Salary Calculator
    Follow on Whatsapp


    Certificate Courses ๐ŸŽ–️

    Pharmaceutical Courses

    Follow Pharmaguideline


    DOCUMENTS ๐Ÿ“‹

    PHARMACEUTICAL DOCUMENTS




    Editable Pharmaceutical Documents in MS-Word Format. Ready to use SOPs, Protocols, Master Plans, Manuals and more...

    View


    adsbypg


    GET APP FOR NEWS UPDATES


    Android App