    SOP for Receipt, Numbering, Usage and Destruction of FBD Filter Bag

    Standard operating procedure to receive, numbering, usage and destruct the FBD Filter Bag.

    1.0 OBJECTIVE

    To lay down the procedure for receipt, numbering, usage and destruction of FBD filter bag.

    2.0 SCOPE

    This SOP shall be applicable for operation of all FBD finger bags in the Production area.

    3.0 RESPONSIBILITY

    3.1 Execution: Operator
    3.2 Checking: Production Pharmacist & Above

    4.0 ACCOUNTABILITY

    HOD-Production / Assigned Designee

    5.0 PROCEDURE

    5.1 RECEIPT OF FBD FINGER BAG

    5.1.1 Raise the requisition note to purchase department with the required specifications for ordering the new finger bag.
    5.1.2 On the receipt of new finger bag from the manufacturer, check the quantity as per delivery challans.
    5.1.3 After receiving the finger bag, if found ok record the entry.
    5.1.4 Check the intactness of the FBD finger bag visually for physical damage, if any and record the same.
    5.1.5 Inform details of damaged finger bag if any, to the purchase department/ manufacturer and return the same.

    5.2 NUMBERING OF FBD FINGER BAG

    5.2.1 Follow the below-mentioned procedure for numbering of FBD finger bag
    5.2.1.1 Number each finger bag as
    5.2.1.1.1 FB/100/01
    5.2.1.1.2 FB - for finger bag
    5.2.1.1.3 100 - for 60 kg capacity FBD.
    5.2.1.1.4 01 - for the number of finger bag.
    5.2.1.1.5 After receiving new finger bag, number the finger bag serially with a subsequent number as FB/100/01
    Note: Number the finger bag after confirming the integrity and record the same in format.

    5.3 STORAGE, ISSUE & USAGE OF FBD FINGER BAG

    5.3.1 FBD bag should be stored in a polybag and kept into the carets having a lid with “CLEANED” label and maintain a record.
    5.3.2 Production person shall issue the numbered FBD bag to the operator when it required and record it in format.
    5.3.3 Check the intactness of the FBD bag before and after use and record it in format.
    5.3.4 Ensure the cleanliness of the FBD bag both before and after use.
    5.3.5 Whenever there is a product changeover, the operator shall return the cleaned and dried FBD bag with proper “CLEANED” status label to the production person.
    5.3.6 Use only cleaned and numbered (product/API) dedicated FBD finger bag.
    Related: SOP for Tablet Granulation, Compression and Coating

    5.4 DESTRUCTION OF FBD FINGER BAG

    5.4.1 If the finger bag found damage, torn or defective during use or at the time of receipt should be destroyed.
    5.4.2 Before sending the finger bag to scarp yard for destruction, cut the finger bag by using a scissor.
    5.4.3 Record the entry of destruction in format.

    6.0 ABBREVIATIONS

    6.1 SOP: Standard Operating Procedure
    6.2 Q.A.: Quality Assurance
    6.3 HOD: Head of The Department
    Get editable documentsView List

    No comments:

    Post a Comment

    Please don't spam. Comments having links would not be published.


    Popular Categories ๐Ÿท️

    QA SOPs QC SOPs Micro SOPs HVAC Production SOPs Stores SOPs Checklists Maintenance SOPs HPLC Sterile GLP Validation Protocols Water System GDP Regulatory Maintenance Calibration Warning Letters Education B.Pharmacy Regulatory Updates
    Online Courses Salary Calculator
    Follow on Whatsapp


    Certificate Courses ๐ŸŽ–️

    Pharmaceutical Courses

    Follow Pharmaguideline


    DOCUMENTS ๐Ÿ“‹

    PHARMACEUTICAL DOCUMENTS




    Editable Pharmaceutical Documents in MS-Word Format. Ready to use SOPs, Protocols, Master Plans, Manuals and more...

    View


    adsbypg


    GET APP FOR NEWS UPDATES


    Android App