Cleaning Validation Limits | Calculation and Criteria

Learn how to calculate Cleaning Validation Limits using PDE, MACO, swab and rinse sampling, recovery factors and GMP acceptance criteria in pharma.
Cleaning validation limits refer to scientifically determined acceptance criteria which set the maximum acceptable level of residues of previous products, cleaning agents or other relevant contaminants, on pharmaceutical equipment surfaces post-cleaning, which will be used to manufacture the new product. These criteria help ensure cross-contamination and protect the patients from any accidental exposure to the previous products.
Cleaning Validation Limits
Establishing correct limits forms one of the most crucial aspects of cleaning validation. It may happen that a cleaning procedure regularly removes all the visible residues, but we cannot verify if it is successful to remove the all contaminants if there are no scientifically acceptable acceptance criteria and methods to verify it.

According to current Good Manufacturing Practices (GMP) requirements, it is now preferred to use health-based exposure limits (HBELs) including Permitted Daily Exposure (PDE), in case of evaluation of potential carry-over risk in shared manufacturing spaces for pharmaceuticals.

Approaches to Establishing Cleaning Validation Limits

In the past, there have been various methods to establish residue specification limits. The scientific validity and regulatory acceptance levels will differ for each of the methods discussed here.

1. Health-Based Exposure Limit (HBEL)

The health-based exposure limit represents an exposure level of a substance that will not cause any adverse health effects. The PDE and the Acceptable Daily Exposure (ADE) have both been defined as examples of health-based values.

The PDE should be derived using toxicological and pharmacological assessments taking into account all relevant safety data and critical adverse effects. It is also dependent on the various exposure routes and appropriate adjustment factors.

An individual with suitable qualifications should develop or assess the PDE and other similar derived health-based parameters, but they cannot merely use the therapeutic dose value or other surrogate parameter without a suitable scientific basis.

2. The 10 ppm Criterion

The traditional 10 ppm threshold serves to limit the amount of the previous product's API from being carried over to the next product to a maximum of 10 mg per kg.

It may be easy to use but does not consider possible differences in toxicity, pharmaco-dynamics or exposure in patients, and may be inadequate for use with highly potent compounds.

A 10 ppm threshold may be applied in addition and as an extra conservative criterion when relevant, but this shouldn't be seen as replacing a health-based approach.

3. Therapeutic Dose Criterion

The therapeutic dose approach uses the principle that no more than 1/1000 of the minimum therapeutic daily dose of the prior active ingredient shall exist within the maximum daily dose of the next active ingredient.

However, the traditional method has a limitation in that the fixed safety factor does not take into account the pharmacological toxicological properties associated with any given pharmaceutical compound. Thus, the traditional method does not supersede a scientifically determined HBEL.

4. Visually Clean Criterion

The visual clean standard dictates that equipment surfaces should appear visually clean as a result of the cleaning procedure approved for that device or operation. In the case when product residues, stain marks, or traces of a cleaning agent are observed, those observations must be considered.

While this routine inspection can provide valuable qualitative feedback on cleaning procedures, visual inspections are usually not considered a sufficient criteria for approving validation.

Calculation of Maximum Allowable Carryover (MACO)

The Maximum Allowable Carryover is the highest quantity of active ingredients of any previous product, which may be carried over to subsequent batches of any product, given certain conditions.

PDE-Based MACO Formula

MACO (mg) = PDE of Product A × Minimum Batch Size of Product B / Maximum Daily Dose of Product B

Where:
Product A - previous product.
Product B - subsequent product.
PDE is expressed in mg/day.
Batch size and daily dose of subsequent product must be expressed in the same mass measurement.

Maximum daily dose represents the total mass of finished product being consumed per day, and not just the mass of its active ingredients.

Practical Calculation

For example, let us consider two products that share the same equipment.

Parameter Value
PDE of Product A 0.02 mg/day
Minimum batch size of Product B 100 kg
Maximum daily dose of Product B 2 g/day

Conversion from kg to grams:
100 kg = 100,000 g
MACO = (0.02 x 100,000) / 2 = 1,000 mg

MACO is calculated as per the given product combinations, which does not automatically imply that it becomes the routine cleaning acceptance limit. In other words, a more restrictive operational limit could potentially be established through cleaning process capability and risk analysis.

Converting MACO into Swab and Rinse Limits

MACO would apply to the respective shared equipment train. However, QC laboratories report swab or rinse sampling individual test results and not the total residue. Therefore, MACO needs to be converted into sampling limits which may be measured.

Swab Sampling Limit

This is one of the possible approaches to calculate the residue limit per unit of shared product contact surface.

The surface residue limit (mg/cm²) can be calculated as MACO / sum of shared surface area.

Using a previous example we assume:
MACO = 1000 mg
Shared surface area = 50 000 cm²
Swab sampling area = 25 cm²
Surface residue limit = 1000 / 50000 = 0.02 mg/cm²
Swab limit = 0.02 × 25 = 0.5 mg
Swab acceptance limit is 500 ยตg per 25 cm²

This calculation assumes uniform allocation of residue over all shared surface area. In reality, it may not be so as some surfaces may be harder to clean, hence sampling points would need to consider these areas.

Rinse Sampling Limit

For properly defined rinse sampling processes, the calculated rinse limit can be expressed as follows:

Rinse Limit (mg/L) = Allocated Allowable Residue (mg) / Rinse Volume (L)

An allowable residue of 1,000 mg may be associated with a 100 L rinse volume for an appropriate piece of equipment, and theoretically the corresponding rinse limit would be 10 mg/L.

It is important to calculate this limit based on real equipment coverage, real rinse volumes, real sampling procedures and demonstrated recovery rates. Full equipment train MACO values should never be applied per piece of equipment on its own.

Correct Application of the Recovery Factor

Sampling and recovery studies are performed to determine what portion of any residue may be removed using the defined sampling and recovery procedures.

The sample swab limit may be accepted as 500 ยตg, while an overall recovery factor of 80% has been determined.

Using the recovery factor to adjust the acceptance limit becomes:
500 ยตg × 0.80 = 400 ยตg

It should also be noted that the actual measured result can be divided by 0.80, which will also yield a final value when compared with the initial limit of 500 ยตg.

As long as the calculation is performed correctly, both methods will produce the same result. The established protocol will specify which method will be used.

Limits on Cleaning Agents and Microbial Contamination

1. Cleaning Agent Residues

Detergents and cleaning agents require scientifically justified acceptance criteria depending on their composition and their toxicological and functional properties.

Suitable analysis methods might include chemical-specific analyses, total organic carbon (TOC) analysis or conductivity measurement where applicable.

The conductivity close to that of purified water cannot confirm the absence of detergent residue.

2. Microbial Acceptance Criteria

Microbial criteria should take into account the manufacturing process, product characteristics, equipment design, clean-in-place times, and risks of contamination.

It should be noted that there is no singular microbial criteria value that will apply to all pharmaceutical manufacturing equipment. It is important to consider endotoxin limits where relevant.

Common Mistakes in Cleaning Limits Calculations

In reviewing cleaning validation calculations, there are particular areas of caution in the following:
  • The inconsistent units being used for both batch size and daily dose.
  • Incorrect PDE values or wrong exposure routes being applied.
  • Not counting the common product-contact surface areas in equipment areas calculation.
  • The MACO has been applied in full independently to multiple equipment pieces.
  • Selection of the analytical method which has quantitation limits above the acceptance criteria.
  • Incorrect application for recovery corrections.
  • Neglecting to revisit cleaning limits in case of change to products, batch sizes, or equipments involved.
Note: Even though the test results have been found below analytical LOQ, such a test result is not a valid proof of compliance if the LOQ is higher than the applicable cleaning limit.

QA has to verify and validate the input data for calculations, toxicological assessment of PDE, recording of the equipment surface area and sampling rationale, and suitability of analytical method before the validation protocol is approved.

Cleaning validation limits should link the required level of patient safety with quantifiable equipment cleaning targets. PDE-based MACO calculations provide a scientific basis for cleaning limits. However, the successful application of these calculations depends on having good quality equipment data, sampling that is representative of a product's lifecycle, recovery correction of samples that are appropriately selected and a sensitive enough analytical method to detect residues. A limit which is mathematically correct is not useful if the cleaning validation strategy cannot provide evidence that equipment will consistently be compliant with this limit.
Get ready to use editable Validation Protocols in MS-Word FormatView List





is a prominent Pharmaceutical Quality Assurance expert, consultant and the founder of Pharmaguideline. With over 22 years of hands-on experience in cGMP-compliant manufacturing environments, he specializes in establishing validation protocols, sterile area controls and data integrity systems. Ankur routinely interprets international regulatory frameworks (including FDA, EMA and ICH guidelines) to help global pharmaceutical professionals ensure strict regulatory compliance and operational excellence. Connect with Ankur on LinkedIn. Need Help: Ask Question