    SOP for Safe and Effective Operations of the Air Compressors

    Standard operating procedure of safe and effective operation of air compressor.

    1.0 OBJECTIVE

    To lay down the procedure for safe and effective operations of the Air Compressors.

    2.0 SCOPE

    This SOP shall be applicable for Air Compressors.

    3.0 RESPONSIBILITY

    Operator/Officer

    4.0 ACCOUNTABILITY

    Head of Engineering

    5.0 PROCEDURE

    5.1 For Starting of the Air Compressors

    5.1.1 Ensure inlet and outlet valves are open of cooling tower pump.
    5.1.2 Press the “Green push button” of Cooling Tower pump (Air Compressor) and press the “Green push button” of Cooling Tower fan.
    5.1.3 Ensure that the water pressure is within the 1 kg/Cm² to 3 kg/ Cm².
    5.1.4 Turn the “Main switch” of Air Compressor on its operating panel.
    5.1.5 Keep control rotary switch in “ON” position.
    5.1.6 There will be alarm; press the Mute button, the alarm will be off.
    5.1.7 Press “Acknowledge” button and Reset button.
    5.1.8 Press “Green push button” for starting the compressor.
    5.1.9 See the Air pressure on the pressure gauge. After it reaches 4 Kg / Cm² open the receiver valve.
    5.1.10 The compressor will go in unload position at pressure 8.2 Kg/ Cm² to 8.8 Kg/ Cm² and it will go in load position when the pressure drops to 7.0 Kg/ Cm² to 7.6 Kg/ Cm².
    5.1.11 Based on the requirement of Air in the plant or Air Pressure is lower than 7.0 Kg/ Cm² at M.S. receiver in the load position, start one more Air Compressor.

    5.2 For Stopping of the Air Compressors

    5.2.1 Press the “Red” push button on the Air Compressor panel to switch off.
    5.2.2 Drain the Air Receiver after switching of the Air Compressor.
    5.2.3 “Turn off” the main switch on Air Compressor panel.
    5.2.4 Press “Red push button” of Cooling Tower Pump (Air Compressor).
    5.2.5 Press “Red push button” of Cooling Tower Fan.

    6.0 ABBREVIATIONS

    6.1 SOP: Standard Operating Procedure
    6.2 Kg: Kilogram
    6.3 Cm: Centimeter
    Get editable documentsView List

    No comments:

    Post a Comment

    Please don't spam. Comments having links would not be published.


    Popular Categories ๐Ÿท️

    QA SOPs QC SOPs Micro SOPs HVAC Production SOPs Stores SOPs Checklists Maintenance SOPs HPLC Sterile GLP Validation Protocols Water System GDP Regulatory Maintenance Calibration Warning Letters Education B.Pharmacy
    Online Courses Salary Calculator
    Follow on Whatsapp


    Certificate Courses ๐ŸŽ–️

    Pharmaceutical Courses

    Follow Pharmaguideline


    DOCUMENTS ๐Ÿ“‹

    PHARMACEUTICAL DOCUMENTS




    Editable Pharmaceutical Documents in MS-Word Format. Ready to use SOPs, Protocols, Master Plans, Manuals and more...

    View


    adsbypg


    GET APP FOR NEWS UPDATES


    Android App