    SOP for Cleaning of Sampling Equipment

    Standard operating procedure to clean the sampling equipment.

    1.0 OBJECTIVE

    To lay down the procedure for cleaning of sampling equipment.

    2.0 SCOPE

    This SOP is applicable to the procedure for cleaning of sampling equipment.

    3.0 RESPONSIBILITY

    Officer/ Executive - Quality Control

    4.0 ACCOUNTABILITY

    Manager – Quality Control

    5.0 PROCEDURE

    5.1 For Scoops/ Spoons

    5.1.1 Clean the sampling devices with running tap water followed by TEEPOL/LABOLENE 0.5 % soap solution to remove adhering material.
    5.1.2 Finally rinse with purified water.
    5.1.3 Check the cleanliness physically and clean again if it is necessary.
    5.1.4 Dry in a hot air oven at 60 °C ± 5°C for 30 minutes.
    5.1.5 Put the clean and dried equipment in a poly-bag and keep it at appropriate place.

    5.2 For sampling pipettes (Glass)

    5.2.1 Clean the equipment with running tap water followed by TEEPOL/LABOLENE 0.5 % soap solution to remove adhering material and rinse.
    5.2.2 Finally rinse with purified water.
    5.2.3 Check the cleanliness physically and clean again if it is necessary.
    5.2.4 Keep the washed tubes for draining on the stand meant for the same.
    6.2.5 After the tubes are dried the ends are covered with poly-bags.

    5.3 For sampling rods (Stainless Steel)

    5.3.1 Clean the things with running tap water followed by TEEPOL/LABOLENE 0.5 % soap solution to remove obvious adhering particles.
    6.3.2 Finally rinse with purified water.
    6.3.3 Check the cleanliness physically and clean again if required
    6.3.4 Wrap the clean and dried equipment in a poly-bag & keep it in appropriate place.
    6.4 After cleaning record to be maintained.
    6.5 After cleaning sampler can be used with in 48 hours.

    6.0 ABBREVIATIONS

    6.1 SOP - Standard Operating Procedure
    6.2 No. - Number
    6.3 QA - Quality Assurance
    6.4 CCF - Change control format
    6.5 NA - Not applicable
    6.6 QC - Quality Control
    Get editable documentsView List

    No comments:

    Post a Comment

    Please don't spam. Comments having links would not be published.


    Popular Categories ๐Ÿท️

    QA SOPs QC SOPs Micro SOPs HVAC Production SOPs Stores SOPs Checklists Maintenance SOPs HPLC Sterile GLP Validation Protocols Water System GDP Regulatory Maintenance Calibration Warning Letters Education B.Pharmacy Regulatory Updates
    Online Courses Salary Calculator
    Follow on Whatsapp


    Certificate Courses ๐ŸŽ–️

    Pharmaceutical Courses

    Follow Pharmaguideline


    DOCUMENTS ๐Ÿ“‹

    PHARMACEUTICAL DOCUMENTS




    Editable Pharmaceutical Documents in MS-Word Format. Ready to use SOPs, Protocols, Master Plans, Manuals and more...

    View


    adsbypg


    GET APP FOR NEWS UPDATES


    Android App