SOP for Volume Delivering Systems (Peristaltic Pump)

Standard operating procedure of Volume Delivering Systems (Peristaltic Pump) used in tablet coating.

1.0 OBJECTIVE

To lay down the procedure for Operation of Volume Delivering Systems (Peristaltic Pump).

2.0 SCOPE

This SOP shall be applicable to Volume Delivering Systems (Peristaltic Pump) in Coating Area.

3.0 RESPONSIBILITY

3.1 Execution: Operator
3.2 Checking: Production Pharmacist & Above

4.0 ACCOUNTABILITY

HOD-Production / Assigned Designee

5.0 PROCEDURE

5.1 PERISTALTIC PUMP

5.1.1 Check the cleanliness of the Peristaltic Pump.
5.1.2 Switch “ON” the mains.
5.1.3 Check & set the Peristaltic Pump to required R.P.M. with adjusting knob.
5.1.4 Check for continuous flow of solvent.
5.1.5 After obtaining required R.P.M, check the volume of solution delivered with the help of calibrated measuring cylinder and starts compressed air to spray gun.
5.1.6 Check the spray and start coating as per the procedure.
5.1.7 Switch “OFF” the mains after completion of the operation.
5.1.8 Affix “To Be Cleaned” Label and fill “Equipment Log Book”.

6.0 ABBREVIATIONS

6.1 SOP : Standard Operating Procedure
6.2 R.P.M : Revolution Per Minute
6.3 Q.A. : Quality Assurance
6.4 HOD : Head of The Department
Get ready to use editable SOPs in MS-Word FormatView List





is a prominent Pharmaceutical Quality Assurance expert, consultant and the founder of Pharmaguideline. With over 22 years of hands-on experience in cGMP-compliant manufacturing environments, he specializes in establishing validation protocols, sterile area controls and data integrity systems. Ankur routinely interprets international regulatory frameworks (including FDA, EMA and ICH guidelines) to help global pharmaceutical professionals ensure strict regulatory compliance and operational excellence. Connect with Ankur on LinkedIn. Need Help: Ask Question