A lot of pharma professionals have the confusion regarding the concept of water content (moisture content) and loss on drying. Both have a considerable difference to understand.

Water content is determined by the Karl Fischer titration method and it consists of only water i.e moisture content. The results do not contain other volatile matter except the water.

Loss on drying (LOD) is determined by heating the sample below its melting point in an oven and it includes all volatile matter including water content and solvents.
Moisture content determinationLoss on Drying is an unspecific analytical technique removing not only water but all other volatile impurities like alcohol etc. from a sample.

The degree of drying depends upon, 1) Temperature 2) Drying time
LOD or total moisture content analysis of Pharmaceutical products can include both bound (e.g. water of hydration) & free water.
In cases there are additional traces of other volatile impurities present, like alcohol; LOD may be higher than water content.
In other cases, LOD may be lower than water content, as bound crystal water may not be removed by heating.
% LOD = % Water content - % water molecule in the API
The Loss on Drying Test is designed to measure the amount of water and volatile matters in a sample when the sample is dried under specified conditions. e.g 105°C, 3 hours.

The nature of the drug substance that is to be weighed and used in compounding a prescription must be known exactly. If the substance is a hydrate, its anhydrous equivalent weight may need to be calculated. On the other hand, if there is adsorbed moisture present that is either specified on a certificate of analysis or that is determined in the pharmacy immediately before the drug substance is used by the procedure under Loss on Drying, this information must be used when calculating the amount of drug substance that is to be weighed in order to determine the exact amount of anhydrous drug substance required.





Ankur Choudhary is India's first professional pharmaceutical blogger, author and founder of pharmaguideline.com, a widely-read pharmaceutical blog since 2008. Sign-up for the free email updates for your daily dose of pharmaceutical tips.
.moc.enilediugamrahp@ofni :liamENeed Help: Ask Question


9 comments: Post Yours! Read Comment Policy ▼

  1. nice differenciation

    ReplyDelete
  2. nice differenciation

    ReplyDelete
  3. Very useful information, thanks for the initiation in guiding the people of pharma industry.

    ReplyDelete
  4. Tq u very much sir

    ReplyDelete
  5. There are innumerable things to know this One is great platform thanks alot

    ReplyDelete
  6. what are the benfits to use the water content test instead of LOD and reason for changing the test from LOD to water content in finished product

    ReplyDelete
  7. thanks for this information, it's really useful

    ReplyDelete

Please don't spam. Comments having links would not be published.


Popular Categories

QA SOPs QC SOPs Micro SOPs HVAC Production SOPs Stores SOPs Checklists Maintenance SOPs HPLC Sterile GLP Validation Protocols Water System GDP Regulatory Maintenance Calibration Warning Letters Education B.Pharmacy
Online Courses


Follow Pharmaguideline


DOCUMENTS

PHARMACEUTICAL DOCUMENTS




Editable Pharmaceutical Documents in MS-Word Format. Ready to use SOPs, Protocols, Master Plans, Manuals and more...

View


adsbypg


Recent Posts