ISO-14644-1 Classification of Air Cleanliness
Cleanliness class designations and quantity have changed from FS209E (see table A). Along with the obvious change to metric measure of air volume, ISO 14644-1 adds three additional classes - two cleaner than Class 10 and one dirtier than Class 100,000. 
Airborne Particulate Cleanliness Classes
Airborne Particulate Cleanliness Classes
| 
CLASS | 
Number of
  Particles per Cubic Meter by Micrometer Size | |||||
| 
0.1 um | 
0.2 um | 
0.3 um | 
0.5 um | 
1 um | 
5 um | |
| 
ISO 1 | 
10 | 
2 | 
- | 
- | 
- | 
- | 
| 
ISO 2 | 
100 | 
24 | 
10 | 
4 | 
- | 
- | 
| 
ISO 3 | 
1,000 | 
237 | 
102 | 
35 | 
8 | 
- | 
| 
ISO 4 | 
10,000 | 
2,370 | 
1,020 | 
352 | 
83 | 
- | 
| 
ISO 5 | 
100,000 | 
23,700 | 
10,200 | 
3,520 | 
832 | 
29 | 
| 
ISO 6 | 
1,000,000 | 
237,000 | 
102,000 | 
35,200 | 
8,320 | 
293 | 
| 
ISO 7 | 
NA | 
NA | 
NA | 
352,000 | 
83,200 | 
2,930 | 
| 
ISO 8 | 
NA | 
NA | 
NA | 
3,520,000 | 
832,000 | 
29,300 | 
| 
ISO 9 | 
NA | 
NA | 
NA | 
35,200,000 | 
8,320,000 | 
293,000 | 
Table B 
Airborne Particulate Cleanliness Class Comparison
| 
ISO
  14644-1 | 
FED STD
  209E | |
| 
1 | 
NA | 
NA | 
| 
2 | 
NA | 
NA | 
| 
3 | 
1 | 
M1.5 | 
| 
4 | 
10 | 
M2.5 | 
| 
5 | 
100 | 
M3.5 | 
| 
6 | 
1,000 | 
M4.5 | 
| 
7 | 
10,000 | 
M5.5 | 
| 
8 | 
100,000 | 
M6.5 | 
| 
9 | 
NA | 
NA | 
ISO 14644-2 determines the type and frequency of testing required to conform with the standard. Table C indicates which tests are mandatory and table E indicates which tests are optional.
Table C
Strategic Testing(Required)
Table 1 Schedule of tests to demonstrate continuing compliance
| 
Test Parameter | 
Class | 
Maximum
  Time Interval | 
Test
  Procedure | 
| 
Particle Count Test | 
<= ISO
  5 | 
6 Months | 
ISO
  14644-1 Annex A | 
| 
Recovery | 
> ISO 5 | 
12 Months | 
ISO
  14644-1 Annex A | 
| 
Air Pressure Difference | 
All
  Classes | 
12 Months | 
ISO
  14644-1 Annex B5 | 
| 
Airflow | 
All
  Classes | 
12 Months | 
ISO
  14644-1 Annex B4 | 
Table D
Strategic Testing (Required)
 
Strategic Testing (Required)
Table 2 Schedule of additional optional tests
| 
Test
  Parameter | 
Class | 
Maximum
  Time Interval | 
Test
  Procedure | 
| 
Installed Filter Leakage | 
All
  Classes | 
24 Months | 
ISO
  14644-3 Annex B6 | 
| 
Containment Leakage | 
All
  Classes | 
24 Months | 
ISO
  14644-3 Annex B4 | 
| 
Recovery | 
All
  Classes | 
24 Months | 
ISO
  14644-3 Annex B13 | 
| 
Airflow Visualization | 
All
  Classes | 
24 Months | 
ISO
  14644-3 Annex B7 | 