SOP for Cleaning of S.S. Vessel and Utensils

Standard operating procedure to clean the S.S. Vessel and Utensils

1.0 OBJECTIVE:

To lay down the cleaning procedure for S.S. Vessel and Utensils.

2.0 SCOPE:

This SCP shall be applicable for S.S. Vessel and Utensils used in Production area.

3.0 RESPONSIBILITY:

3.1 Execution :Operator
3.2 Checking :Pharmacist and Above

4.0 ACCOUNTABILITY:

HOD-Production

5.0 PROCEDURE:

5.1 Initially remove all the residual material from the parts to be cleaned.
5.2 Wash with Potable water & scrub if necessary.
5.3 Wash with Potable water at least two times till the entire residue is washed off & then used 2.5 % “Teepol” solutions.
5.4 Further clean the parts with hot water & finally rinse with purified Water.
5.5 Wipe with 70% v/v solution of Isopropyl Alcohol (IPA).
5.6 Allow the parts to dry.
5.7 Affix “Cleaned” label & cover the parts adequately.
5.8 Check the parts for cleanliness before use & re-clean if not used within 72 hours.

6.0 ABBREVIATIONS:

SCP :Standard Cleaning Procedure
IPA :Isopropyl Alcohol
Get ready to use editable SOPs in MS-Word FormatView List





is a prominent Pharmaceutical Quality Assurance expert, consultant and the founder of Pharmaguideline. With over 22 years of hands-on experience in cGMP-compliant manufacturing environments, he specializes in establishing validation protocols, sterile area controls and data integrity systems. Ankur routinely interprets international regulatory frameworks (including FDA, EMA and ICH guidelines) to help global pharmaceutical professionals ensure strict regulatory compliance and operational excellence. Connect with Ankur on LinkedIn. Need Help: Ask Question