Calculation for Capacity of Tablet Coating Machine

Capacity of tablet coating machine is calculated by brim volume of the coating pan and the bulk density of the tablets.
The quantity of tablets used for coating in coating pan plays a great role in getting good coating results. The capacity of the coating machine pan should be calculated to get a uniform coating. Inadequate quantity of tablets used for coating in the pan may cause different coating problems.

Tablet Coating Machine
The working capacity of the coating machine is determined by the brim volume of the coating pan. Brim volume is the total volume of the water when the pan is fully filled at its current position. Brim volume is different from the total volume of the pan. Brim volume is given in the equipment manual.

Maximum capacity of the pan is calculated by the brim volume and the bulk density of the tablets. It is simply determined that how much tablets are required to fill the pan up to the brim.
Maximum Capacity of Coating Pan (Kg) = Brim Volume (ltrs) X Bulk Density of Tablets (mg/ml)

The minimum capacity of the coating pan is simply 60% of the maximum capacity calculated above.
Minimum Capacity of coating Pan (Kg) = Brim Volume (ltrs) X Bulk Density of Tablets (mg/ml) X 60/100

For example:
48” coating machine pan generally has brim volume 160 ltrs
Bulk Density of Tablets = 0.62 g/ml
Maximum Capacity = 160 X 0.62 = 99.2 kg
Minimum Capacity = 160 X 0.62 x 60/100 = 59.52 Kg

The maximum and minimum capacity of the coating machine depends upon the size and shape of the tablets because bulk density changes when the shape and size of the tablets change. Small tablets of the same formulation have higher bulk density than the big tablets.





Ankur Choudhary is India's first professional pharmaceutical blogger, author and founder of pharmaguideline.com, a widely-read pharmaceutical blog since 2008. Sign-up for the free email updates for your daily dose of pharmaceutical tips.
.moc.enilediugamrahp@ofni :liamENeed Help: Ask Question


9 comments: Post Yours! Read Comment Policy ▼

  1. Very good information

    ReplyDelete
  2. Very very good information. I don't know before it!

    ReplyDelete
  3. It's basic information, expecting It to elaborate in details. Thanks

    ReplyDelete
  4. thanks, further please add calculation of brim volume and scaleup aspects in coating.

    ReplyDelete
  5. Thanks for v.good information.
    One thing is not cleared that in formulae for calculating coatig pan capicity BULK DENSITY of tab.is given in mg/ml.while in example calculation, it is in g/ml.please make it clear which one is right.

    ReplyDelete
  6. Thank you, Helpful information...

    ReplyDelete

Please don't spam. Comments having links would not be published.


Popular Categories

QA SOPs QC SOPs Micro SOPs HVAC Production SOPs Stores SOPs Checklists Maintenance SOPs HPLC Sterile GLP Validation Protocols Water System GDP Regulatory Maintenance Calibration Warning Letters Education B.Pharmacy
Online Courses


Follow Pharmaguideline


DOCUMENTS

PHARMACEUTICAL DOCUMENTS




Editable Pharmaceutical Documents in MS-Word Format. Ready to use SOPs, Protocols, Master Plans, Manuals and more...

View


adsbypg


Recent Posts