An unsuccessful validation doesn't imply that the process, device, supply, or procedure in the pharmaceutical industry is unusable. What it means is that the result of the study isn't desirable and it's either unpredictable or it fails to provide sufficient proof that the parameters specified beforehand have been achieved. The next step is to find and analyze the cause for failure and discover the consequences of the failure, which would provide information on the solution to the problem.
The idea behind Validation CAPA is to correct the issue discovered in the present case of validation failure, analyze the cause of failure, and prevent this scenario from occurring in the future. Validation CAPA should be documented properly and linked with validation failure case study, investigation of the failure, and analysis of the problem. It would not make sense to just repeat the test to obtain positive results.
The failure could include:
For instance, if purified water system fails a microbial acceptance criterion during the qualification, the investigation of sampling point, sampling technique, cleaning status, operation of the water system, lab method, and possible sources of contamination should be conducted. If the sample is repeated without investigating these factors, another result can be achieved without providing an explanation of the original failure.
Evaluate pertinent records such as:
Take for instance a cleaning validation experiment where the residue is over the acceptable limits. The possible reasons for this could be incorrect cleaning parameters, ineffective cleaning process, equipment design specs, bad sampling points, or an analytical problem.
When conducting the analysis of all possible reasons, the investigation should check every supposed reason against the facts. In case the cause is traced to some human error, it is important to find out what caused the system, training, supervision or controls in the procedures to fail. “Human error” on its own is not the sufficient reason for the further preventive steps to be taken.
Though immediate correction may restore the affected system and/or equipment, it does not necessarily mean that the objective of validation has been fulfilled. After correction, the affected test may still have to be done according to the agreed scheme.
CAPA should specify the changes to be introduced, people responsible for the changes, and the date of the implementation. The measures have to be clear enough for verification. For instance, “provide additional training” could be too weak if the analysis does not find training to be the leading issue and the required level is not identified.
In case of the equipment qualification failure, the next step is to check if the equipment has been utilized prior to the resolution of the problem and whether the operations carried out could have been affected. In the case of the process validation, relevant batches, critical process parameters, critical quality characteristics, and data from the new product must be assessed.
When checking for equipment cleaning validation, one should determine if the production of the equipment has already started, what products have been processed using this equipment, and whether any sticky substances require further investigation.
The evaluation must include similar instruments, systems, materials, or procedures. Similar design problems can be the reason for a failure of the original validation study.
In cases when the quality of a product or the safety of a patient is in question, the issue must be escalated according to the deviation and quality risk management processes that are in place on the site. Decisions related to the disposition of batch must be made through standard quality system, and not based only on later achieved positive validation result.
Local repair of the device can only require focused requalification of damaged functions. Meanwhile, change in the key process parameter or cleaning process can mean wider scope and need for more validation activities in other fields. Reasoning of the test scope must be documented and approved prior to implementation.
Do not change acceptance criteria retroactively only with the aim of getting a positive result. If the criteria need to be changed for real, the reason for it must have scientific or technical justification, must pass through the change control procedure and be approved prior to usage of the new approach.
Validation report must clearly present the original failure, research source, corrective and preventive actions taken, performed repeat testing and obtained outcomes.
The overall approach adopted for assessment purposes should be defined at the moment of creating the CAPA. Depending on the problem being addressed, the approach may contain elements like:
In case the mounting failure takes place again, the CAPA should be revisited. The original root cause might have been inaccurate, the actions taken failed to eliminate the root cause, or implementation of the CAPA was wrong.
When an inspector comes for an inspection, he may ask why the validation failed, and how the root cause was determined, if the affected batches or systems were examined, and what evidence proves that CAPA was efficient. The organization has to be ready to provide answers to those questions based on contemporaneous records and not retrospective reports.
An unsuccessful validation study provides an excellent chance for the identification of the vulnerabilities in equipment design, process understanding, processes, or control systems. A functional CAPA goes beyond handling the immediate situation. It deals with the root cause of the failure, measures the influence of the failure, sets the grounds for retesting, and makes sure that the issue does not happen again.
The idea behind Validation CAPA is to correct the issue discovered in the present case of validation failure, analyze the cause of failure, and prevent this scenario from occurring in the future. Validation CAPA should be documented properly and linked with validation failure case study, investigation of the failure, and analysis of the problem. It would not make sense to just repeat the test to obtain positive results.
First Decide What the Validation Failure Actually Means
Before launching CAPA, the team needs to identify the type and importance of the failure. Any failure of validation tests may arise from different causes and have different consequences.The failure could include:
- A piece of equipment or a utility working outside the defined acceptance criteria.
- Process conditions that cannot stay within the specified limits.
- Cleaning results that contain higher amount of residues than permissible.
- Validation of a method that doesn’t comply with required characteristics.
- Testing process exposes unsatisfactory installation, malfunction of alarms or bad operation.
- Wrong test results cause valid conclusions to be impossible.
For instance, if purified water system fails a microbial acceptance criterion during the qualification, the investigation of sampling point, sampling technique, cleaning status, operation of the water system, lab method, and possible sources of contamination should be conducted. If the sample is repeated without investigating these factors, another result can be achieved without providing an explanation of the original failure.
Investigate the Root Cause Before Selecting CAPA
The investigation process should take into account the risk and complication level behind the occurrence. The investigation aims to clarify why the result was obtained instead of just recording what has happened.1. Review the complete execution record
The initially approved protocol and study records should be reviewed. The test should be confirmed to have been performed according to the protocol, and whether the acceptance criteria were introduced properly, following unapproved changes.Evaluate pertinent records such as:
- Data of operation of the equipment, calibration progress, and its maintenance.
- BMRs, equipment logs, and process parameters.
- Sampling results, producer's data, calculations, and audit trails of equipment.
- Education records and employee credentials when necessary.
- Conditions of nature, utility reports, and records of resources.
- Previously occurred deviations, repairs, and CAPA of concern.
2. Use a systematic approach to root cause analysis
Various analysis methods like 5 Whys, fishbone diagram, fault-tree analysis, or process mapping can make analysis easier. However, the finding itself does not explain the root cause of the problem. The final solution needs to be backed by evidence.Take for instance a cleaning validation experiment where the residue is over the acceptable limits. The possible reasons for this could be incorrect cleaning parameters, ineffective cleaning process, equipment design specs, bad sampling points, or an analytical problem.
When conducting the analysis of all possible reasons, the investigation should check every supposed reason against the facts. In case the cause is traced to some human error, it is important to find out what caused the system, training, supervision or controls in the procedures to fail. “Human error” on its own is not the sufficient reason for the further preventive steps to be taken.
Separate Immediate Correction From Corrective and Preventive Action
These concepts should not be confused with each other. Correction refers to fixing the problem at hand while ameliorative measure defines the actions taken to eliminate its root cause. Preventive measures extend guarantees against similar issues in the future.| Action Type | Purpose | Example in practice |
| Corrective Measure | Adjustment of the current problem | Repair a disturbed sensor |
| Corrective action | Elimination of the cause of the problem | Correct the installation procedure and introduce a double-check procedure of installation |
| Preventive Measure | Mitigation of possible underground issues | Check installation practices and update qualification checks |
Though immediate correction may restore the affected system and/or equipment, it does not necessarily mean that the objective of validation has been fulfilled. After correction, the affected test may still have to be done according to the agreed scheme.
CAPA should specify the changes to be introduced, people responsible for the changes, and the date of the implementation. The measures have to be clear enough for verification. For instance, “provide additional training” could be too weak if the analysis does not find training to be the leading issue and the required level is not identified.
Assess the Impact on Validation and Product Quality
When a validation fails, it is important to analyze more than just the finding of the test. QA and the tech team must see if the failure calls into question the outcome of the research, the qualification status, the process control or the quality of the product that has already been produced.In case of the equipment qualification failure, the next step is to check if the equipment has been utilized prior to the resolution of the problem and whether the operations carried out could have been affected. In the case of the process validation, relevant batches, critical process parameters, critical quality characteristics, and data from the new product must be assessed.
When checking for equipment cleaning validation, one should determine if the production of the equipment has already started, what products have been processed using this equipment, and whether any sticky substances require further investigation.
The evaluation must include similar instruments, systems, materials, or procedures. Similar design problems can be the reason for a failure of the original validation study.
In cases when the quality of a product or the safety of a patient is in question, the issue must be escalated according to the deviation and quality risk management processes that are in place on the site. Decisions related to the disposition of batch must be made through standard quality system, and not based only on later achieved positive validation result.
Revalidation and Retesting must have Scientific Justification
After managing corrective and preventive actions, a decision about changes that might be needed to prove that issue has been solved must be taken. The scope of retests is determined by the failure, root cause, hazard and impact on validated state.Local repair of the device can only require focused requalification of damaged functions. Meanwhile, change in the key process parameter or cleaning process can mean wider scope and need for more validation activities in other fields. Reasoning of the test scope must be documented and approved prior to implementation.
Do not change acceptance criteria retroactively only with the aim of getting a positive result. If the criteria need to be changed for real, the reason for it must have scientific or technical justification, must pass through the change control procedure and be approved prior to usage of the new approach.
Validation report must clearly present the original failure, research source, corrective and preventive actions taken, performed repeat testing and obtained outcomes.
Verify CAPA Effectiveness, Not Just Completion
The closure in CAPA should not only hinge on actions taken to tackle the CAPA. The assessment of the effectiveness of the actions taken determines whether the original issue is resolved satisfactorily and whether the likelihood of recurrence is minimized.The overall approach adopted for assessment purposes should be defined at the moment of creating the CAPA. Depending on the problem being addressed, the approach may contain elements like:
- Successful re-qualification or re-validation.
- Examination of subsequent batches to see how the process is working.
- Trends analysis of some process parameters or the laboratory findings.
- Studying the related deviations for a certain time window.
- Ensuring the compliance with the modified standard operating procedures.
In case the mounting failure takes place again, the CAPA should be revisited. The original root cause might have been inaccurate, the actions taken failed to eliminate the root cause, or implementation of the CAPA was wrong.
What QA Should Ensure Before Closing Validation CAPA
When closing a validation CAPA, QA needs to ensure that the investigation is based on evidence, the evaluation is concluded, and that every action was executed and verified. All of the supporting documentation should be presented in scientific form and traced back to the right deviation and validation documents.When an inspector comes for an inspection, he may ask why the validation failed, and how the root cause was determined, if the affected batches or systems were examined, and what evidence proves that CAPA was efficient. The organization has to be ready to provide answers to those questions based on contemporaneous records and not retrospective reports.
An unsuccessful validation study provides an excellent chance for the identification of the vulnerabilities in equipment design, process understanding, processes, or control systems. A functional CAPA goes beyond handling the immediate situation. It deals with the root cause of the failure, measures the influence of the failure, sets the grounds for retesting, and makes sure that the issue does not happen again.
Get ready to use editable Validation Protocols in MS-Word FormatView List