Water System Sanitization Validation in Pharma Plants

Learn water system sanitization validation, including thermal and chemical methods, critical parameters, sampling and GMP acceptance criteria.
Pharmaceutical water systems can create conducive environments for the growth of microorganisms in cases where temperature, circulation, and proper hygiene design are not kept in control. There is, in fact, microbial contamination that takes place even in water systems which can generate water complying with conductivity and total organic carbon (TOC) set parameters.
Water System Sanitization Validation
The term sanitization validation of a water system refers to a well-documented process of showing that the process of thermal or chemical sanitization is used to manage microbial issue within the water system without having negative impact on water quality or system pieces.

Thus, it is not enough to have an objective to reduce the count of microorganisms immediately after the process of sanitization. Validation of the process needs to prove that it satisfies the set requirements.

How to Choose the Right Sanitization Technique

In determining the sanitization technique to choose, factors to consider include system designs, water quality, building materials used, temperature of use, contamination risk level, and compatibility of system elements.

1. Thermal Sanitization

Thermal sanitization entails running hot water through a system at a particular temperature and duration. This method is mostly used in stainless steel Purified Water (PW) and Water for Injection (WFI) distribution systems built to handle high temperatures.

The efficiency of thermal sanitization depends on the temperature achieved through the system, rather than the temperature indicated in the heater.

80°C is the most common temperature used in various systems, but it is not recommended to use this temperature or time as a general standard. Each system should establish its own requirements and standards for the use of these parameters.

2. Chemical Sanitization

Chemical sanitization is beneficial for systems that are not able to tolerate high temperatures. The sanitizing agents include hydrogen peroxide, ozone, or peracetic acid, and depend on the design of the system and compatibility with materials.

Validation should ensure the proper concentration of sanitizer, its distribution, time, and effects on microorganisms, as well as breakdown of chemical residues after completion of sanitization prior to the return of the system to operational state.

Systems using ozone could include controlled ozone circulation and ultraviolet installation allowing for ozone destruction prior to delivery of water for pharmaceutical applications.

Parameter Thermal sanitization Chemical sanitization
Main control factor Temperature and time Concentration and time
Distribution verification Temperature mapping Sanitizer concentration
Material compatibility Heat resistance Chemical resistance
Post-cycle action Cooling and quality verification Flushing or sanitizer destruction
Main validation issue Places where heat was insufficient Lack of time or residual sanitizer

Preparations Before Sanitization Validation

Verification of sanitization should start with evaluating the system and determining whether it is qualified for this purpose. An effective sanitization procedure cannot compensate for a bad design of equipment or improper system maintenance.

Design and Readiness of the System

Take the piping and instrumentation diagram (P&ID) and check its compliance with the installation of the system. Pay special attention to areas with low fluid circulations, dead legs, standby pumps, valve assemblies, heat exchangers, storage tanks, and endpoints, which are basically placed in the areas where fluid is needed.

Temperature sensors, flow meters, conductivity meters, and equipment used for checking the concentration of the sanitizing agent should be calibrated accordingly.

The validation plan has to include:
  • Sanitization method, number of cycles, and operation parameters.
  • The worst-case places and points of sampling.
  • The monitoring of temperature or concentration of the sanitizing agent.
  • The time of exposure and conditions of liquid movement.
  • The criteria for microbiological and chemical sampling.
  • The sampling after sanitization and the procedures of system's approval.
  • How many times validation is to be performed and why.
The number or cycles needed to conduct validation in the current situation and the reasons for these validations.

Conducting Thermal Sanitization Validation

Study of Temperature Distribution

Temperature mapping is used to determine whether each component of the water system has been sufficiently treated. The temperature loggers or calibrated sensors should be placed in the locations where the probable cold areas are located.

Those cold areas may be the storage tanks, lines for the supply and return of the cooling liquid, remote points of water consumption, heat exchangers, shut-off pump circuit system, and other places of poor water circulation.

For instance, the temperature in the storage tank may be 80 degrees, whereas, in a far location, it may be only 72 degrees. In this case, if the timer is started with the water in the tank having the proper temperature, the far place will not be sanitized properly.

The time period for which the temperature should be kept should not start until the proper temperature is reached.

Verification of Overall Exposure of the System

The description of the operation must provide information about how the points of use, the pipe branches, and other components were subjected to thermal exposure. The success of the return loop temperature cannot guarantee that all branches are correctly heated.

The temperature profile will be scrutinized for any variations, heat losses, interrupted circulation, or lack of time exposure.

Conducting Chemical Sanitization Validation

Concentration and Duration Validation

The concentration produced in the sanitization tank may be different from the concentration delivered to far-off points in the distribution system during the process of chemical sanitization. The effective concentration may be affected by the dilution and decomposition of the chemical, as well as its interaction with the surfaces present in the system.

The concentration of the sanitizer must be verified at various points in the distribution system and whether or not the sanitizer is used for the prescribed time.

The validation team must also analyze the influence of the sanitizer on membranes, elastomeric materials, sealing materials, equipment, and any other components which are considered sensitive.

Removal of Residual Sanitizer

After conduct of chemical sanitization, the respective system must be flushed, drained, or use a method for destruction of the sanitizer, as appropriate.

To carry out the residual sanitizer test a proper method should be used, which demonstrates applicability of the method for the specified levels of acceptance. Conductivity and TOC may not be sufficient to determine that a specific sanitizer is absent.

Remaining chemicals could have an effect on pharmaceutical products as well as on laboratory tests and microbial recovery. That is why microbiological sampling should consider neutralization of the sanitizer if necessary.

Microbiological Sampling and Acceptance Criteria

Sampling Before and After Sanitization

References taken before cleaning provide information about the microbial condition prior to sanitation. Thus, the outcomes of post-cleaning reference samples provide microbiological quality evidence post-sanitization.

The place from which references are taken needs to represent all storage and distribution systems of water supply, including those that are considered to be the most risky. In addition, references should be taken under very specific flushing conditions, utilizing predetermined sample containers and adhering to defined holding periods for samples.

The method of introducing microorganisms into a working water supply can be performed in order to conduct the sanitation verification test, however, it is inadvisable.

Evaluating Validation Results

Acceptance criteria must include considerations of both test operations and water quality obtained. Items usually consist of proper temperature, recovery rates, time of exposure, microbiological tests final limits of residual sanitizer and water quality required characteristics.

Tests for endotoxins should be carried out only when needed, mainly WFI systems. It should be noted that successful reduction of microbes does not guarantee the removal of endotoxins because conventional sanitizing procedures are not equal to the process of depyrogenation.

In my opinion, if validation were based only on low numbers of microbial count after the treatment it would not be considered appropriate. It is necessary to carry out monitoring during subsequent operating period in order to see whether microbial control is achieved or not.

Establishing the Sanitization Frequency

Frequency of sanitization should be based on any water system performance data, trends of the microbiological contamination, operational conditions and qualifications/validations experiments’ results.

Sanitization can be performed on either daily or weekly basis, or some might even choose other intervals. Weekly sanitization frequency may be considered totally unjustified when used solely because another manufacturing site does so.

Repeated increase in microbe counts before the scheduled sanitization shows the inefficiency of the water treatment process.

Investigating Sanitization Failures and Microbial Recurrence

The reappearance of microbes even after effective sanitization is of great importance. The possible reasons could be due to the survival of biofilms, lack of sufficient time exposure at the valve branches, stagnation, contamination of filters in the vents, insufficient water circulation, and ineffective maintenance practices.

The investigation must link the biological data to the sanitization records, temperature profiles, flow data, maintenance history, and information on validation of the microbial species.

Simply repeating the sanitization process without identifying the cause of the problem will only diminish the number of microbes temporarily without eliminating the contamination. The QA department must analyze the impact on the specific batches of medicine to define the proper CAPA measures.

What need to be remembered is that if changes in such items as the sanitizing agents, cycle conditions, piping configurations, and main system components take place, a change control process should be followed to check the necessity of revalidation.

Successful validation of the water systems sterilization process provides evidence that proper treatment occurred at every stage, the water quality after the cycle meets the requirements, as well as that the required level of microorganism control is maintained in between sanitization cycles. The main evidence of validation is not merely obtaining the proper indices after the cycle but also maintaining such indicators on a regular basis. If there is a problem with microbiological contamination, the objective is not to increase the frequency of sterilization but find out and eliminate the cause of reoccurrence.

Get ready to use editable Validation Protocols in MS-Word FormatView List





is a prominent Pharmaceutical Quality Assurance expert, consultant and the founder of Pharmaguideline. With over 22 years of hands-on experience in cGMP-compliant manufacturing environments, he specializes in establishing validation protocols, sterile area controls and data integrity systems. Ankur routinely interprets international regulatory frameworks (including FDA, EMA and ICH guidelines) to help global pharmaceutical professionals ensure strict regulatory compliance and operational excellence. Connect with Ankur on LinkedIn. Need Help: Ask Question