SOP for Temperature, Humidity and Differential Pressure Monitoring | Pharmaguideline
  •   Pharmaguideline Courses Start Learning
  • Apr 17, 2021

    SOP for Temperature, Humidity and Differential Pressure Monitoring

    Standard operating procedure to monitor the temperature, humidity and differential pressure of microbiology lab.

    1.0 PURPOSE

    To lay down the procedure to monitor the temperature, humidity and differential pressure of microbiology lab.

    2.0 SCOPE

    This is applicable to Microbiology lab

    3.0 RESPONSIBILITY

    Microbiologist

    4.0 ACCOUNTABILITY

    Head of Department

    5.0 PROCEDURE

    5.1 Temperature and Humidity Record

    5.1.1 Precaution
    5.1.1.1 Check and ensure that the wick is fixed on the wet bulb thermometer.
    5.1.1.2 The cistern of the wet bulb should be filled with purified water.
    5.1.1.3 Check and ensure that the wick is wet.
    5.1.1.4 Hygrometer should not keep under direct airflow and in front of the window where direct sun light exposed.
    5.1.2 Procedure For Tempareture
    5.1.2.1 Enter in the respective area and ensure that cistern of the wet bulb is filled with purified water properly.
    5.1.2.2 Check the temperature of the dry and wet bulb and record the value.
    5.1.3 Procedure For Relative Humidity
    5.1.3.1 Calculate relative humidity value by referring humidity chart.
    5.1.3.2 Refer the difference along the top line of the chart.
    5.1.3.3 Follow the column down until level with dry bulb reaching for percentage humidity.
    5.1.3.4 Locations:
    Media preparation room
    MLT and LAL testing room
    Sterility lab
    5.1.4 Frequency: Temperature and RH to be taken three times (Morning, afternoon and evening) in a day.
    5.1.5 Acceptance criteria:
    Temperature: NMT (Not More Than) 25°C
    Relative Humidity: NMT 60%

    5.2 Differential Pressure monitoring

    5.2.1 Enter in the respective area and ensure that all doors of microbiology lab are tightly closed and HVAC in running condition before taking the pressure reading.
    5.2.2 Open the door of respective area and ensure zero (0) set, while the door is opened. Then close door properly
    5.2.3 Take the magnehelic reading in the reference of the negative and positive pressure of rooms and record the value.
    Media preparation
    Air look Media preparation
    Change room
    MLT and LAL testing room
    Corridor
    Sterility lab
    5.2.5 Frequency: Twice a day in morning and afternoon.
    5.2.6 Acceptance criteria:
    5.3 If any discrepancy is observed, inform to Engineering Department and further action should be taken.

    6.0 Abbreviations

    6.1 SOP - Standard operating procedure
    6.2 RH - Relative Humidity
    6.3 NMT - Not More Than
    6.4 NLT - Not Less Than
    6.5 °C - Degree Centigrade
    6.6 % - Percentage
    6.7 HVAC - Heating Ventilation Air Conditioning
    Get editable documentsView List

    No comments:

    Post a Comment

    Please don't spam. Comments having links would not be published.


    Popular Categories ๐Ÿท️

    QA SOPs QC SOPs Micro SOPs HVAC Production SOPs Stores SOPs Checklists Maintenance SOPs HPLC Sterile GLP Validation Protocols Water System GDP Regulatory Maintenance Calibration Warning Letters Education B.Pharmacy
    Online Courses Salary Calculator
    Follow on Whatsapp


    Certificate Courses ๐ŸŽ–️

    Pharmaceutical Courses

    Follow Pharmaguideline


    DOCUMENTS ๐Ÿ“‹

    PHARMACEUTICAL DOCUMENTS




    Editable Pharmaceutical Documents in MS-Word Format. Ready to use SOPs, Protocols, Master Plans, Manuals and more...

    View


    adsbypg


    GET APP FOR NEWS UPDATES


    Android App