    1.0 OBJECTIVE

    To lay down the procedure for Operation of Multimill.

    2.0 SCOPE

    This SOP shall be applicable for Multimill in all Granulation area at Production department.

    3.0 RESPONSIBILITY

    3.1 Execution: Operator
    3.2 Checking: Production Pharmacist & Above

    4.0 ACCOUNTABILITY

    HOD-Production / Assigned Designee

    5.0 PROCEDURE

    5.1 Production person shall ensure the cleanliness of the machine & area and ‘CLEANED’ label on it.
    5.2 Check the integrity of screen before and after the operation and record the observation in “Screen integrity check Log”.
    5.3 Before starting the operation production person get the line clearance from QA person and affix the status label with Product Name, batch details to equipment & area.
    5.4 Fix the beater assembly.
    5.5 Fit the screen of the required size and the hopper properly.
    5.6 Set the Multimill in the required direction (Knife forward / Impact forward) by moving the lever/ knob. Then adjust the required speed by changing the position of V- belt.
    5.7 Tie the poly bag to the discharge chute of Multimill by food grade rubber & keep the poly bag in S.S. In process container and then place a container below the discharge port.
    5.8 Put “ON” the mains, then press the green button and load the material, adjust the chute plate so that material will feed slowly and checks for the smooth functioning of the machine.
    5.9 Control the flow with stopper plate & ensure that the hopper is not charged heavily otherwise the Multimill can get blocked.
    5.10 Put “OFF” the mains after completion of the operation.
    5.11 Affix “To Be Cleaned” label on Multimill & fill the “Equipment Log Book”.

    Note: The new screen is procured it will be inspected and given the new I.D.No. (Identification No.), and if Screen is found torned, with holes or integrity is not ok in it or unsuitable in any respect for usage, then it is to be replaced immediately and record it in“ Sieve/Screen Inward, issuance & Destruction Register”.

    6.0 ABBREVIATIONS

    6.1 SOP: Standard Operating Procedure
    6.2 HOD: Head of The Department
    6.3 S.S.: Stainless Steel
    Get editable documentsView List

    No comments:

    Post a Comment

    Please don't spam. Comments having links would not be published.


    Popular Categories ๐Ÿท️

    QA SOPs QC SOPs Micro SOPs HVAC Production SOPs Stores SOPs Checklists Maintenance SOPs HPLC Sterile GLP Validation Protocols Water System GDP Regulatory Maintenance Calibration Warning Letters Education B.Pharmacy Regulatory Updates
    Online Courses Salary Calculator
    Follow on Whatsapp


    Certificate Courses ๐ŸŽ–️

    Pharmaceutical Courses

    Follow Pharmaguideline


    DOCUMENTS ๐Ÿ“‹

    PHARMACEUTICAL DOCUMENTS




    Editable Pharmaceutical Documents in MS-Word Format. Ready to use SOPs, Protocols, Master Plans, Manuals and more...

    View


    adsbypg


    GET APP FOR NEWS UPDATES


    Android App