SOP for Die Blocking : Pharmaceutical Guidelines

SOP for Die Blocking

Standard operating procedure of die blocking of compression machine.

1.0 OBJECTIVE

To lay down the procedure for Die Blocking.

2.0 SCOPE

This SOP shall be applicable for Die Blocking of compression machine in compression area at Production department.

3.0 RESPONSIBILITY

3.1 Execution: Operator
3.2 Checking: Production Pharmacist & Above

4.0 ACCOUNTABILITY

HOD-Production / Assigned Designee

5.0 PROCEDURE

5.1 In case of any damage of die bore or Punch bore or less quantity of punch die cavity should be blocked with the help of dummy die (die without bore).
5.2 If in case dummy die is not available, following method is to be used for blocking of die:
5.2.1 Cut a piece of Beeswax (solid) & fill in die bore which die is to be blocked & affix the wax with a metal rod with gentle hammering.
5.3 Wipe/scrape the excess wax and clean the turret and adjust the feed frame for further use.
Related: SOP for Ordering, Receiving, Storage, Issue, & Destruction of Dies, Punches

6.0 ABBREVIATIONS

6.1 SOP: Standard Operating Procedure
6.2 Q.A.: Quality Assurance
6.3 HOD: Head of The Department





Ankur Choudhary is India's first professional pharmaceutical blogger, author and founder of Pharmaceutical Guidelines, a widely-read pharmaceutical blog since 2008. Sign-up for the free email updates for your daily dose of pharmaceutical tips.