Water System Sanitization Validation in Pharma Plants

Pharmaceutical water systems can create conducive environments for the growth of microorganisms in cases where temperature, circulation, and proper hygiene design are not kept in control. There is, in fact, microbial contamination that takes place even in water systems which can generate water complying with conductivity and total organic carbon (TOC) set parameters.

Cleaning Validation for Granulation Equipment in GMP

It is particularly difficult to clean granulation equipment. The accumulation of pharmaceutical powders, wet granules, binders as well as active pharmaceutical ingredients (APIs) happens on the equipment's surface, and in parts that are hard to reach. The contamination of following batches and deterioration of product quality may happen due to the residues that remain after cleaning.

Six Sigma Tools for Pharmaceutical Manufacturing

Six Sigma represents an organized and evidence-based set of techniques for processing variations in manufacturing while searching for the root cause of defects and attempting to achieve better functional results. Six Sigma is particularly applicable to pharmaceutical processes and their improvement by introducing such applicable solutions as achieving better consistency of tablet weight, minimizi…

Electronic Batch Record Validation for GMP Compliance

Utilization of Electronic Batch Records (EBRs) in pharmaceutical production involves the development, application, verification and storage of the electronic batch record. Moreover, Electronic Batch Record Validation refers to the actions documented in order to demonstrate that the EBR system performs its appropriate tasks, provides reliable and accurate batch records and complies with regulation…

Validation CAPA | Managing Failures and Preventing Recurrence

An unsuccessful validation doesn't imply that the process, device, supply, or procedure in the pharmaceutical industry is unusable. What it means is that the result of the study isn't desirable and it's either unpredictable or it fails to provide sufficient proof that the parameters specified beforehand have been achieved. The next step is to find and analyze the cause for failure and…

Process Validation for Contract Manufacturing Products

Validating a process for contract manufacturing products is a joint effort between the Product Owner and the contract manufacturing organization (CMO). The aim of validation is to prove that the process can manufacture a product according to the specifications set forth.

Sterilization Failure in Pharmaceuticals | Investigation and CAPA

Failure of sterilization in pharmaceutical production refers to a sterilization process that either does not comply with its validated specifications or fails to give suitable guarantees of sterility. It can be either a failure in sterilization cycles, inadequate time used for contact with a sterilizing agent, having a positive biological indicator, a break in aseptic condition or finding contami…

Common Validation Mistakes in Pharma Manufacturing

The purpose of validation in pharmaceutical production is to give documented proof that the processes and instruments being used are in compliance with their intended utilization and capable of being carried out successfully. This can, however, stop being true once the focus shifts from scientific proof to filling in the necessary documents only.

Sterilization Validation Failure | Investigation Guide

Sterilization validation failure means the proof available does not support the idea of achievement of the given sterilization process acceptance criteria. It may include poor temperature distribution, poor heat penetration, biologic indicators (BI) failure, wrong cycle parameters, as well as inability to prove the sterilization conditions.

LIMS Validation in Pharmaceutical QC Laboratories

LIMS (Laboratory Information Management System) refers to a computerized system that pharmaceutical laboratories use to keep track of and organize test samples, testing tasks, test results, laboratory protocols and records. It is one of the methods through which LIMS validation is done, whereby documented proof is provided to show how appropriate the system is and that it is capable of supporting…

Measuring Validation Effectiveness in Pharma GMP

Validation can be considered successful only when it presents dependable proofs that a process, equipment, utility, analytical technique, or IT system is under control during its entire lifetime and can fulfill its intended function. Therefore, assessment of the productivity of validation presupposes more than counting number of completed protocols, fully authorized reports and qualified activiti…

Risk Assessment Tools Used in Pharmaceutical Validation

Risk assessment plays a crucial role in pharmaceutical validation as it enables the ascertainment of different process stages, machinery processes, systems, and qualities that require the most attention. The tools used for validation risk analysis available in pharmaceutical industries include failure mode and effect analysis, failure mode, effects, and criticality analysis, fault tree analysis, …

Risk-Based Validation in the Pharmaceutical Industry

Risk-Based Validation refers to the process of organizing validation activities of pharmaceutical process, system or method based on the actual risks for product quality, patient safety and data integrity. It assumes that scientific knowledge and quality risk management (QRM) should help in identification of critical points and areas of validation, to which the organization should pay the maximum…

Validation Audit Checklist for Pharmaceutical GMP

Validation audit evaluates a pharmaceutical site's validation process to determine if the validation program is scientifically acceptable, appropriately documented and implemented in accordance with authorized processes and remains throughout the lifecycle of equipment, utilities, processes and systems. Validation Audit Checklist allows auditors to assess whether enough validation documents e…

Process Validation Failure Investigation and Root Cause

Process validation failure takes place when a process does not satisfy the requirements established beforehand for design validation and does not show stable process performance or sufficient supporting evidence for validation. The investigation of the process validation failure is the record-keeping and scientifically rational process of understanding what happened, why it happened, if the quali…

Cleaning Validation Microbial Limits and Acceptance Criteria

Microbial acceptance criteria for cleaning validation are used to show that the cleaning process provides the required level of control over microbial contamination for the intended use of the equipment. A single universal microbial limit is not a valid approach to all pharmaceutical cleaning validation studies. The microbial limits should be scientifically justified based on product, process, eq…

Cleaning Validation Recovery Study | Swab and Rinse

A cleaning validation recovery study is used to determine the effectiveness of a specified sampling technique in collecting residues from pharmaceutical equipment and rendering them available for analysis. A cleaning validation recovery study will assess the efficiency of swab/rinse sampling technique and determine if the resulting analytical data is a good representative of residual levels (if a…

Clean Hold Time Study in Pharmaceutical Manufacturing

A Clean Hold Time Study (CHT) determines how long cleaned equipment can stay clean and unused. Establishing the clean hold time is an integral part of cleaning validation as it identifies the necessary storage conditions plus the kind of protection from contamination that is needed in order to keep the equipment clean for the period of Clean Hold Time.

Cleaning Validation Acceptance Criteria | Setting Limits

Cleaning validation acceptance criteria state the maximum allowed levels of product residues, cleaning agents and other relevant contaminants left on pharmaceutical production equipment after its cleanliness, in order to scientifically justify, quantify and sustain these limits to protect the next product from potential contamination or cross-contamination.

Validation Data Review | What QA Must Check

The validation data review is the process of critically analyzing the data generated during validation or qualification studies with the objective of checking whether the study was conducted according to the protocol, whether the data obtained is valid, whether the acceptance criteria were realized and whether the conclusions are based on scientific understanding. In addition to simply summarizin…