SOP for Cleaning of Cad Mill : Pharmaceutical Guidelines

SOP for Cleaning of Cad Mill

Standard operating procedure to clean the Cad Mill.

1.0 OBJECTIVE:

To lay down the cleaning procedure for cad mill.

2.0 SCOPE:

This SCP shall be applicable for cad mill used in Granulation area in Production department.

3.0 RESPONSIBILITY:

3.1 Execution :Operator
3.2 Checking :Pharmacist and Above

4.0 ACCOUNTABILITY:

HOD-Production

5.0 PROCEDURE:

5.1 Put “OFF” the electrical supply and cover motor, starter, with polythene bag.
5.2 Remove hopper, blade chamber, screen and blades & clean with 25 liter Potable water.
5.3 Further clean with 2.5 % “Teepol” solution using scrubber. Rinse with 25 liter potable water thoroughly.
5.4 Apply 20 liter hot water to all the cleaned items and allow the water to drain. Finally rinse with about 30 liter purified water.
5.5 Wipe out with dry clean lint free cloth and with 70% IPA.
5.6 Assemble the parts and affix "Cleaned" Label and fill “Equipment Log Book” (Annexure-I).
5.7 Re-clean if not used within 72 hours.

6.0 ABBREVIATIONS:

SCP :Standard Cleaning Procedure
IPA :Isopropyl Alcohol





Ankur Choudhary is India's first professional pharmaceutical blogger, author and founder of Pharmaceutical Guidelines, a widely-read pharmaceutical blog since 2008. Sign-up for the free email updates for your daily dose of pharmaceutical tips.
[email protected] :liamENeed Help: Ask Question


Click Here

No comments: Read Comment Policy ▼